On This Page 
    2.14: Require Method URL
    This test ensures that the merchant is allowing sufficient time (10 seconds) for the
                issuer to complete device data collection.
Card Numbers
        The Method URL process runs before the authentication request to ensure device data is
                collected properly. The enrollment check of the card account should not start until
                after the device data collection (DDC) response is received. This test verifies that
                there is enough time to collect the BIN of the issuer and to transmit it. This test
                attempts to collect the nine-digit BIN of the card number and verifies that the
                delay between the DDC request and the response is at least 7 seconds long. The test
                fails when fewer than nine digits of the BIN are collected or when the delay between
                the DDC request and response is too short in duration. 
Do not run this test when your system does not collect device data. When device data
                is not collected, an older version of the EMV 3-D Secure protocol is automatically
                used, and the transaction is automatically assessed as a higher risk. 
| Card Type | Test Card Number | 
|---|---|
| Visa                                                                               Card Type = 001 | 400010                                                                           00 0000 0000 | 
Results for the Check Enrollment Service
            VERes enrolled = 
Y
PARes status = 
Y
CAVV = <CAVV value>
ECI value = 
07
E-Commerce Indicator (ECI) Values
            The following table lists the expected ECI or Collection Indicator values for each network.
| Network | ECI Raw Value | 
|---|---|
| Visa | 07 | 
Action
            If your device data collection method implements correctly and EMV 3-D Secure
                processing occurs, the test transaction produces a Frictionless Success result. A
                failure is indicated when PARes status = 
C
. With the failure, a
                warning message opens to explain the cause of the test failure.